| Usage (Overall) |
| Suitable Applications: | Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155 ATM, 622 ATM, 250MHz Category 6 |
| Physical Characteristics (Overall) |
| # Pairs | 4 |
| AWG | 23 |
| Stranding | Solid |
| Conductor Material | BC - Bare Copper |
| Total Number of Conductors: | 8 |
| Ground Wire (Y/N): | N |
| Insulation Material | PP - Polypropylene |
| Wall Thickness (mm) | 0.254 |
| Dia. (mm) | 1.092 |
| Inner Jacket Material | PVC |
| Nom Wall (mm) | 0.508 |
| Nom. Dia. (mm) | 6.858 |
| Inner Jacket Ripcord: | Yes |
| Outer Shield Trade Name | Beldfoil® |
| Type | Tape |
| Outer Shield Material | Aluminum Foil - Polyester Tape |
| Coverage (%) | 100.000 |
| AWG | 24 |
| Stranding | 7x32 |
| Drain Wire Conductor Material | TC - Tinned Copper |
| Outer Jacket Trade Name | Datatuff® |
| Outer Jacket Material | Industrial Grade PVC - Polyvinyl Chloride |
| Nom. Wall Thickness (mm) | 0.762 |
| Nom. Dia. (mm) | 8.509 |
| Outer Jacket Ripcord: | No |
| Overall Cabling Fillers: | X-Spline Center Member |
| Overall Nominal Diametre: | 8.509 mm |
| Number | 1 |
| Color | White/Blue Stripe & Blue |
| Mechanical Characteristics (Overall) |
| Storage Temperature Range: | -40°C To +80°C |
| Installation Temperature Range: | -25°C To +75°C |
| Operating Temperature Range: | -40°C To +75°C |
| UL Temperature Rating: | 75°C |
| Bulk Cable Weight: | 65.481 Kg/Km |
| Max. Recommended Pulling Tension: | 177.928 N |
| Min. Bend Radius/Minor Axis: | 101.600 mm |
| Applicable Specifications and Agency Compliance (Overall) |
| NEC/(UL) Specification: | CMR, CMX-Outdoor |
| CEC/C(UL) Specification: | CMR |
| AWM Specification: | UL Style 21047 |
| EU Directive 2011/65/EU (ROHS II): | Yes |
| Other Standards: | ISO/IEC 11801 ed 2.1 (2008) Class E |
| EU CE Mark: | Yes |
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2002/95/EC (RoHS): | Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): | 10/09/2009 |
| EU Directive 2002/96/EC (WEEE): | Yes |
| EU Directive 2003/11/EC (BFR): | Yes |
| CA Prop 65 (CJ for Wire & Cable): | Yes |
| MII Order #39 (China RoHS): | Yes |
| Telecommunications Standards: | Category 6 - TIA 568.C.2 |
| Other Specification: | UL Verified to Category 6 |
| UL Flame Test: | UL1666 Riser |
| C(UL) Flame Test: | FT4 |
| IEEE Flame Test: | 1202 |
| Suitability - Indoor: | Yes |
| Suitability - Outdoor: | Yes |
| Suitability - Aerial: | Yes |
| Suitability - Burial: | No |
| Sunlight Resistance: | Yes |
| Oil Resistance: | Yes |
| Plenum (Y/N): | No |
| Electrical Characteristics (Overall) |
| Maximum Capacitance Unbalance (pF/100 m): | 330 |
| Notes (Overall) |
| Notes: | US Patent #'s 5, 606, 151; 5, 734, 126. Operating temperatures are subject to length de-rating. Cable passes -40C Cold Bend per UL 1581. Not intended for 600 V eletrical power delivery. |