Belden Low Capacitance Computer Cable for EIA RS485 / DMX Control 1 Pair 24AWG – 305m Reel

Part #: 9841 0601000

24 AWG stranded (7x32) TC conductors, polyethylene insulation, twisted pairs, overall Beldfoil® (100% coverage) + TC braid shield (90% coverage), 24 AWG stranded TC drain wire, PVC jacket.
  • Overview
  • Specifications
  • Downloads
  • Overview
24 AWG stranded (7x32) TC conductors, polyethylene insulation, twisted pairs, overall Beldfoil® (100% coverage) + TC braid shield (90% coverage), 24 AWG stranded TC drain wire, PVC jacket.

Please call Madison for Project Quotations on Belden Products, or for pricing on any unlisted Belden products

  • Specifications
Physical Characteristics (Overall)
# Pairs1
AWG24
Stranding7x32
Conductor MaterialTC - Tinned Copper
Total Number of Conductors:2
Insulation MaterialPE - Polyethylene
Wall Thickness (mm)0.584
Layer #1
Outer Shield Trade NameBeldfoil® (w/ shorting fold)
TypeTape
Outer Shield MaterialAluminum Foil-Polyester Tape
Coverage (%)100.000
Stranding7x#32
Drain Wire Conductor MaterialTC - Tinned Copper
Outer Jacket MaterialPVC - Polyvinyl Chloride
Nom. Wall Thickness (mm)0.889
Overall Cabling Fillers:Fibrous Polypropylene
Length (mm)63.500
DirectionLeft Hand
Twists (twist/m)15.749
Overall Nominal Diametre:5.893 mm
ColorWhite/Blue and Blue/White
Mechanical Characteristics (Overall)
Operating Temperature Range:-30°C To +90°C
UL Temperature Rating:80°C (UL AWM Style 2919)
Bulk Cable Weight:53.575 Kg/Km
Max. Recommended Pulling Tension:321.605 N
Min. Bend Radius/Minor Axis:63.500 mm
Applicable Specifications and Agency Compliance (Overall)
NEC/(UL) Specification:CM
NEC Articles:800
CEC/C(UL) Specification:CM
AWM Specification:UL Style 2919 (30 V 80°C)
EU Directive 2011/65/EU (ROHS II):Yes
EU CE Mark:Yes
EU Directive 2000/53/EC (ELV):Yes
EU Directive 2002/95/EC (RoHS):Yes
EU RoHS Compliance Date (mm/dd/yyyy):01/01/2004
EU Directive 2002/96/EC (WEEE):Yes
EU Directive 2003/11/EC (BFR):Yes
CA Prop 65 (CJ for Wire & Cable):Yes
MII Order #39 (China RoHS):Yes
UL Flame Test:UL1685 UL Loading
CSA Flame Test:FT1
Suitability - Indoor:Yes
Plenum (Y/N):No
Plenum Number:82841, 89841
  • Downloads