Garlands larger conductor EIA RS-232 cables are based on the successful MC14 series but include an overall aluminium laminate screen with an integrated drain wire. These products are designed for low bit rate serial data applications requiring an unbalanced connection.
Typical applications include the interconnection of DTE (Data Terminal Equipment) such as printers, fax's and consoles. This RS-232 cable can also be used in the industrial sector where the lower resistance of the 14 strand conductor is seen as a benefit in long runs.
The MC14 "S" series cables can be used in this environment to interconnect PLC's, sensors, data loggers, keyboards and other peripheral devices. In the security market, this product range can be used to connect alarm and fire sensors, door strikes and card readers to monitoring or alarm systems.
General | |
Pack Size | 500m |
Applicable Standards | AS/ACIF S008, BS4737-3.30 |
Suitable Applications | For inter-connecting wiring, suitable for use in Security/Intruded Alarm system; Use in low voltage/low current applications such as intercommunication. |
ROHS Compliant | Yes |
A-Tick (Yes/No) | yes |
No. Cores | 4 |
Conductor Characteristics | |
AWG | 21 |
Stranding (mm) | 14/0.2 |
Area (mm2) | 0.44 |
Diameter (mm) | 0.87 |
Material | BC |
Insulation | |
Material | PVC |
Nominal Thickness (mm) | 0.3 |
Nominal OD (mm) | 1.5 |
Drain Wire | |
AWG | 24 |
Stranding | 7 |
Area (mm2) | 0.22 |
Diameter (mm) | 0.2 |
Material | TC |
Screen | |
Material | Al. Polyester Tape |
Coverage (%) | 1 |
Filler | |
Material | Al. Polyester Tape |
Coverage (%) | 1 |
Outer Sheath | |
Material | PVC |
Colour | GREY |
Nominal Thickness (mm) | 0.7 |
Nominal OD (mm) | 5.65 |
Physical Characteristics | |
Insulation - Elongation at BBA | >100% |
Outer Sheath - Elongation at BBA | >100% |
Tensile Strength Before Aging | >12MPa |
Electrical Properties | |
Max. Conductor DC Resistance @ 20°C | 45.2Ω/km |
Min. Insulation Resistance @ 20°C | 50MΩ.km |
Voltage Test: Conductor to core | 1.5 kV ac/1min |
Voltage Test: Core to sheath | 3.0 kV ac/1min |
Mechanical Properties | |
Operating Temp Range | -15 to 70°C |
Max. Recommended Pulling Tension | 123N |
Min Bend Radius (Install) | 56mm |
Approximate Mass(kgs/100m) | 4.8kg/100m |
Supply Information | |
Supply Information - Pack Type | Wooden Reel |
Dimensions | W39 x 21.8cm |