  • Specifications
Physical Characteristics (Overall)
# Conductors4
# Pairs1
AWG22
Stranding19x34
Conductor MaterialTC - Tinned Copper
Insulation MaterialPVC - Polyvinyl Chloride
Layer #22 AWG Pair
TypeTape
Inner Shield MaterialAluminum Foil-Polyester Tape
Coverage (%)100
TypeBraid
Outer Shield MaterialTC - Tinned Copper
Coverage (%)65
Drain Wire Conductor MaterialTC - Tinned Copper
Outer Jacket MaterialPVC - Polyvinyl Chloride
Nom. Wall Thickness (mm)0.813
Overall Nominal Diametre:7.112 mm
Number22 AWG Pair
ColorRed & Black
Mechanical Characteristics (Overall)
Operating Temperature Range:-20°C To +75°C
UL Temperature Rating:75°C
Bulk Cable Weight:61.016 Kg/Km
Max. Recommended Pulling Tension:289.133 N
Min. Bend Radius/Minor Axis:69.850 mm
Applicable Specifications and Agency Compliance (Overall)
NEC/(UL) Specification:CL2, CMG
CEC/C(UL) Specification:CMG
AWM Specification:UL Style 20201 (600 V 75°C)
EU Directive 2011/65/EU (ROHS II):Yes
EU CE Mark:Yes
EU Directive 2000/53/EC (ELV):Yes
EU Directive 2002/95/EC (RoHS):Yes
EU RoHS Compliance Date (mm/dd/yyyy):04/01/2005
EU Directive 2002/96/EC (WEEE):Yes
EU Directive 2003/11/EC (BFR):Yes
CA Prop 65 (CJ for Wire & Cable):Yes
MII Order #39 (China RoHS):Yes
Other Specification:ODVA Class 2 Thin
UL Flame Test:UL1685 FT4 Loading
CSA Flame Test:FT4
Sunlight Resistance:Yes
Oil Resistance:Yes
Plenum (Y/N):No
Notes (Overall)
Notes:Flex Life: +/- 90 Degree Flex Test, 2" Diametre, 2 lbs. tension: 2000 Cycles minimum. Meter marks on jacket to aid users in installation. ODVA DevaiceNet is an Open DeviceNet Vendor Association, Inc. trademark.
  • Downloads