Belden Multi-Conductor – Category 5 DataTuff® Cables

Part #: 7919A 0061000

24 AWG solid bare copper conductors, twisted pairs, polyolefin insulation, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain wire, industrial grade sunlight- and oil-resistant PVC jacket, rip cord. Sequential marking at two foot intervals
  • Overview
  • Specifications
  • Overview
24 AWG solid bare copper conductors, twisted pairs, polyolefin insulation, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain wire, industrial grade sunlight- and oil-resistant PVC jacket, rip cord. Sequential marking at two foot intervals
  • Specifications
Usage (Overall)
Suitable Applications:Industrial Ethernet Cable, Harsh Environments, 100MHz Category 5e, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, RS-422, CMX - Outdoor, RJ-45 Compatible, Noisy Environments
Physical Characteristics (Overall)
# Pairs4
AWG24
StrandingSolid
Conductor MaterialBC - Bare Copper
Total Number of Conductors:8
Insulation MaterialPO - Polyolefin
Wall Thickness (mm)0.254
Outer Shield Trade NameBeldfoil®
TypeTape
Outer Shield MaterialAluminum Foil-Polyester Tape
Coverage (%)100
Stranding7x32
Drain Wire Conductor MaterialTC - Tinned Copper
Outer Jacket MaterialIndustrial Grade PVC - Polyvinyl Chloride
Outer Jacket Ripcord:No
Overall Nominal Diametre:6.731 mm
Number1
ColorWhite/Blue Stripe & Blue
Mechanical Characteristics (Overall)
Installation Temperature Range:-25°C To +75°C
Operating Temperature Range:-40°C To +75°C
Bulk Cable Weight:44.646 Kg/Km
Max. Recommended Pulling Tension:111.205 N
Min. Bend Radius/Minor Axis:25.400 mm
Applicable Specifications and Agency Compliance (Overall)
NEC/(UL) Specification:CMR, CMX-Outdoor, UL444
CEC/C(UL) Specification:CMR
EU Directive 2011/65/EU (ROHS II):Yes
EU Directive 2000/53/EC (ELV):Yes
EU Directive 2002/95/EC (RoHS):Yes
EU RoHS Compliance Date (mm/dd/yyyy):01/01/2004
EU Directive 2002/96/EC (WEEE):Yes
EU Directive 2003/11/EC (BFR):Yes
CA Prop 65 (CJ for Wire & Cable):Yes
MII Order #39 (China RoHS):Yes
PMSHA Specification:P-07-KA060004
Other Specification:NEMA WC-63.1 Category 5e, UL verified to Category 5e
Countrywww.belden.com/p
UL Flame Test:UL1666 Riser
CSA Flame Test:FT4
Suitability - Outdoor:Yes
Sunlight Resistance:Yes
Oil Resistance:Yes
Plenum (Y/N):No
Electrical Characteristics (Overall)
Maximum Capacitance Unbalance (pF/100 m):330
Notes (Overall)
Notes:Operating temperatures are subject to length de-rating. Cable passes -40°C Cold Bend per UL 1581.